As my title states, 2008 CAT 930G, Stalls when dumping bucket, and think a Ride Control issue may be related, but wouldn't surprise me if it coincidental either. Had Ride controller Accumulater Recharged, new valve and solenoid on Ride Control Valvebody, Seems to work intermittently, then quits altogether. The Relay behind the entry switch loses constant power as soon as joystick is moved to dump position. It is the constant power, not the switched power to turn ride control on and off operated on the dash, 100% sure of this.
This Loader has been nothing but trouble since day 1, in the last 8 months alone my employer has spent over 20 grand in parts on this machine, countless hours of down time, and we can't get an 8 hour shift out of this thing, has 5500hrs!. It's very frustrating trying to keep this thing at work. Everyday is a new troubleshooting adventure!
This Loader has been nothing but trouble since day 1, in the last 8 months alone my employer has spent over 20 grand in parts on this machine, countless hours of down time, and we can't get an 8 hour shift out of this thing, has 5500hrs!. It's very frustrating trying to keep this thing at work. Everyday is a new troubleshooting adventure!